ABB electrical accessory WG39KK41 2CPX056144R9999

ABB electrical accessory WG39KK41 2CPX056144R9999

Ref. no. 2CPX056144R9999ABBEAN 4011617561446
  • BrandABB
  • SeriesWG39KK41
  • Depth225 mm
  • Max. cross section outgoing cable120 mm²
  • Max. cross section connection cable120 mm²
  • Nominal voltage (Un)415 V
  • Rated insulation voltage Ui690 V

All parameters ›

Description

Transformer meter cabinet ABB 2CPX056144R9999: nominal voltage (Un) 415 V, rated frequency 50 Hz, mounting method surface mounting, rated impulse voltage 6 kV. Transformer meter cabinet. Dimensions 800 × 1400 × 225 mm (W × H × D). Degree of protection IP55.

Technical data

SeriesWG39KK41
Electrical
Max. cross section outgoing cable120 mm²
Max. cross section connection cable120 mm²
Nominal voltage (Un)415 V
Rated insulation voltage Ui690 V
Resistance to current surges25 kA
Continuous current Inc200 A
Rated frequency50 Hz
Rated impulse voltage6 kV
Rated short-time withstand current Icw25 kA
Number of poles busbar (connection space, power side)5-pole
Number of switching device panels1
Meter equipped with control cable ductNo
Meter equipped with push-in distribution terminal blockNo
Termination point meter locationYes
Suitable for metering transformer conversion boardNo
Disconnecting point, system sideSwitch disconnector (low voltage)
Disconnecting point, power sideKnife blade fuse holder
With metering transformer conversion boardNo
Test terminal, number of poles16
Lower current feedWith busbar
With power supply connectorYes
Mechanical
Depth225 mm
Width800 mm
Height1400 mm
ColorGrey
Number of doors2
Number of indirect meters1
Number of locks1
RAL colour number7035
Impact resistanceIK08
Suitable for outdoor installationNo
Mounting methodSurface mounting
With mounting plateNo
Operating conditions
Operating temperature5–25 °C
IP protection ratingIP55
Pollution degree3
Other
Electromagnetic compatibility (EMC)Category B
Number of fields3
Meter equipped with optical communication headNo
Overvoltage protectionPrepared
Earthing systemTN-S
Rated load factor RDF1
Equipment of additional transformer meter compartmentTest terminal
Equipment of transformer compartmentBusbar
With primary wiringYes
With secondary wiringYes

Documents

Related products

Product safety information (GPSR)

Manufacturer
Legrand SNC, 128 avenue du Maréchal de Lattre de Tassigny, 87045 Limoges Cedex, France · www.legrand.com
Responsible person in the EU / importer
Legrand Polska sp. z o.o., ul. Waryńskiego 20, 57-200 Ząbkowice Śląskie, Poland · www.legrand.pl