Legrand DPX moulded case circuit breaker 3P 1250 A 36 kA with measurement electronic trip unit IP30 DPX3 1600 S10 422963
- BrandLegrand
- SeriesDPX 250 1600
- Ultimate breaking capacity Icu36 kA
- Depth215 mm
- Rated current In1250 A
- Width210 mm
- Height320 mm
Legrand DPX moulded case circuit breaker 3P, 1250 A, 36 kA, with measurement, electronic trip unit, reference 422963, rated current In 1250 A, overload release setting range 250…1250 A. A moulded case circuit breaker is used to switch distribution circuits and protect them against overloads and short circuits. Parameters: rated current In 1250 A; number of poles 3; breaking capacity Icu 36 kA; overload release setting range 250…1250 A; short-circuit release setting range 15.000 A; voltage type AC; width 210 mm, height 320 mm, depth 215 mm. Design: with trip indicator, with integrated undervoltage release, supplied with protection device.
| Series | DPX 250 1600 |
|---|---|
| Ultimate breaking capacity Icu | 36 kA |
| Depth | 215 mm |
| Rated current In | 1250 A |
| Width | 210 mm |
| Height | 320 mm |
| Battery or accumulator | Battery |
| Battery weight (g) for Type 1 | 1.1 |
| Device design | Permanently installed device |
| For TH rail mounting | No |
| Supply direction | From top or bottom |
| Colour | Grey |
| Number of batteries | 1 |
| Number of poles | 3 |
| Number of auxiliary changeover contacts | 3 |
| Labelling area | Yes |
| RAL number | 7035 |
| Type 1 number | 2 |
| Optional DIN (TH) rail mounting | No |
| Optional motor operator | Yes |
| IEC designation | CR1616 |
| Terminal marking | No |
| Terminal cross-section (min-max) | 120-800 mm² |
| Actuator type | Switch |
| Connection cable type | Rigid |
| Voltage type | AC |
| Main contact connection type | Screw connection |
| Battery type/technology | Lithium |
| Degree of protection (IP) | IP30 |
| Storage temperature (min-max) | -40-85 °C |
| Total weight of the batteries (Type 1) | 2.2 |
| Type 1 location | Product contains a battery |
| Main circuit terminal location | Front |
| Supplied with protection device | Yes |
| Integrated motor operator | No |
| Frequency range (min-max) | 50-60 Hz |
| Rated voltage range (min-max) | 220-690 V |
| Short-time delay release setting range (min-max) | 1875-12500 A |
| Overload release setting range (min-max) | 250-1250 A |
| Short-circuit release setting range (min-max) | 15.000-15.000 A |
| Operating temperature range (min-max) | -5-70 °C |
| Contains battery and/or accumulator | Yes |
| With trip indicator | Yes |
| With integrated undervoltage release | Yes |
| Integrated earth fault protection | No |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz | 36 kA |
| Rated uninterrupted current Iu | 1250 A |
Technical data according to the manufacturer's documentation.