Region and language

Prices include VAT of the delivery country.

Delivery and paymentsConfiguratorsArticles +48 793 996 171
Photo coming soon

Legrand DPX moulded case circuit breaker 3P 500 A 50 kA with measurement electronic trip unit IP30 DPX3 1600 S10 422910

Ref. no. 422910 (4229 10)LegrandEAN 3414972259699
  • BrandLegrand
  • SeriesDPX 250 1600
  • Ultimate breaking capacity Icu50 kA
  • Depth215 mm
  • Rated current In500 A
  • Width210 mm
  • Height320 mm

All parameters ›

Description

Legrand DPX moulded case circuit breaker 3P, 500 A, 50 kA, with measurement, electronic trip unit (catalogue number 422910). A moulded case circuit breaker is used to switch distribution circuits and protect them against overloads and short circuits. Key parameters: rated current In 500 A; number of poles 3; breaking capacity Icu 50 kA; overload release setting range 100…500 A; short-circuit release setting range 15.000 A; voltage type AC; width 210 mm, height 320 mm, depth 215 mm. Features: with trip indicator, with integrated undervoltage release, supplied with protection device.

Technical data

SeriesDPX 250 1600
Ultimate breaking capacity Icu50 kA
Depth215 mm
Rated current In500 A
Width210 mm
Height320 mm
Battery or accumulatorBattery
Battery weight (g) for Type 11.1
Device designPermanently installed device
For TH rail mountingNo
Supply directionFrom top or bottom
ColourGrey
Number of batteries1
Number of poles3
Number of auxiliary changeover contacts3
Labelling areaYes
RAL number7035
Type 1 number2
Optional DIN (TH) rail mountingNo
Optional motor operatorYes
IEC designationCR1616
Terminal markingNo
Terminal cross-section (min-max)35-300 mm²
Actuator typeSwitch
Connection cable typeFlexible or rigid
Voltage typeAC
Main contact connection typeScrew connection
Battery type/technologyLithium
Degree of protection (IP)IP30
Storage temperature (min-max)-40-85 °C
Total weight of the batteries (Type 1)2.2
Type 1 locationProduct contains a battery
Main circuit terminal locationFront
Supplied with protection deviceYes
Integrated motor operatorNo
Frequency range (min-max)50-60 Hz
Rated voltage range (min-max)220-690 V
Short-time delay release setting range (min-max)750-5000 A
Overload release setting range (min-max)100-500 A
Short-circuit release setting range (min-max)15.000-15.000 A
Operating temperature range (min-max)-5-70 °C
Contains battery and/or accumulatorYes
With trip indicatorYes
With integrated undervoltage releaseYes
Integrated earth fault protectionNo
Rated short-circuit breaking capacity Icu at 400 V, 50 Hz50 kA
Rated uninterrupted current Iu500 A

Technical data according to the manufacturer's documentation.

Documents

Related products

Product safety information (GPSR)

Manufacturer
Legrand SNC, 128 avenue du Maréchal de Lattre de Tassigny, 87045 Limoges Cedex, France · www.legrand.com
Responsible person in the EU / importer
Legrand Polska sp. z o.o., ul. Waryńskiego 20, 57-200 Ząbkowice Śląskie, Poland · www.legrand.pl

Instructions and safety information — in the manufacturer's documents above or on the manufacturer's website.