Legrand DPX moulded case circuit breaker 3P 630 A 50 kA electronic trip unit IP30 DPX3 1600 S10 422930
- BrandLegrand
- SeriesDPX 250 1600
- Ultimate breaking capacity Icu50 kA
- Depth215 mm
- Rated current In630 A
- Width210 mm
- Height320 mm
Legrand DPX moulded case circuit breaker 3P, 630 A, 50 kA, electronic trip unit, IP30, reference 422930, rated current In 630 A, overload release setting range 126…630 A. Features: with trip indicator, with integrated undervoltage release, supplied with protection device. Main parameters: rated current In 630 A; number of poles 3; breaking capacity Icu 50 kA; overload release setting range 126…630 A; short-circuit release setting range 15.000 A; voltage type AC; width 210 mm, height 320 mm, depth 215 mm. A moulded case circuit breaker is used to switch distribution circuits and protect them against overloads and short circuits.
| Series | DPX 250 1600 |
|---|---|
| Ultimate breaking capacity Icu | 50 kA |
| Depth | 215 mm |
| Rated current In | 630 A |
| Width | 210 mm |
| Height | 320 mm |
| Battery or accumulator | Battery |
| Battery weight (g) for Type 1 | 1.1 |
| Device design | Permanently installed device |
| For TH rail mounting | No |
| Supply direction | From top or bottom |
| Colour | Grey |
| Number of batteries | 1 |
| Number of poles | 3 |
| Number of auxiliary changeover contacts | 3 |
| Labelling area | Yes |
| RAL number | 7035 |
| Type 1 number | 2 |
| Optional DIN (TH) rail mounting | No |
| Optional motor operator | Yes |
| IEC designation | CR1616 |
| Terminal marking | No |
| Terminal cross-section (min-max) | 50-370 mm² |
| Actuator type | Switch |
| Connection cable type | Flexible or rigid |
| Voltage type | AC |
| Main contact connection type | Screw connection |
| Battery type/technology | Lithium |
| Degree of protection (IP) | IP30 |
| Storage temperature (min-max) | -40-85 °C |
| Total weight of the batteries (Type 1) | 2.2 |
| Type 1 location | Product contains a battery |
| Main circuit terminal location | Front |
| Supplied with protection device | Yes |
| Integrated motor operator | No |
| Frequency range (min-max) | 50-60 Hz |
| Rated voltage range (min-max) | 220-690 V |
| Short-time delay release setting range (min-max) | 945-6300 A |
| Overload release setting range (min-max) | 126-630 A |
| Short-circuit release setting range (min-max) | 15.000-15.000 A |
| Operating temperature range (min-max) | -5-70 °C |
| Contains battery and/or accumulator | Yes |
| With trip indicator | Yes |
| With integrated undervoltage release | Yes |
| Integrated earth fault protection | No |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz | 50 kA |
| Rated uninterrupted current Iu | 630 A |
Technical data according to the manufacturer's documentation.
Instructions and safety information — in the manufacturer's documents above or on the manufacturer's website.
We use cookies to ensure the website works properly and to give you a better experience. Privacy Policy