Legrand DPX moulded case circuit breaker 4P 320 A 70 kA with measurement electronic trip unit IP30 DPX3 630 S10 422886
- BrandLegrand
- SeriesDPX 250 1600
- Ultimate breaking capacity Icu70 kA
- Depth170 mm
- Rated current In320 A
- Width270 mm
- Height150 mm
Legrand DPX moulded case circuit breaker 4P, 320 A, 70 kA, with measurement, electronic trip unit, reference 422886. Application and mounting: for TH rail mounting. Features: optional DIN TH rail mounting, supplied with protection device, optional motor operator. Parameters: rated current In 320 A; breaking capacity Icu 70 kA; overload release setting range 0.2…1 A; number of auxiliary changeover contacts 1; voltage type AC; width 270 mm, height 150 mm, depth 170 mm. A moulded case circuit breaker is used to switch distribution circuits and protect them against overloads and short circuits.
| Series | DPX 250 1600 |
|---|---|
| Ultimate breaking capacity Icu | 70 kA |
| Depth | 170 mm |
| Rated current In | 320 A |
| Width | 270 mm |
| Height | 150 mm |
| Device design | Complete device in housing |
| For TH rail mounting | Yes |
| Supply direction | From top or bottom |
| Colour | Grey |
| Number of poles | 3 |
| Number of auxiliary changeover contacts | 1 |
| Number of auxiliary NC contacts | 1 |
| Number of auxiliary NO contacts | 1 |
| Labelling area | Yes |
| Impact resistance | IK07 |
| Optional DIN (TH) rail mounting | Yes |
| Optional motor operator | Yes |
| Terminal marking | No |
| Terminal cross-section (min-max) | 90 - 150 mm² |
| Actuator type | Switch |
| Connection cable type | Flexible or rigid |
| Voltage type | AC |
| Main contact connection type | Screw connection |
| Degree of protection (IP) | IP30 |
| Storage temperature (min-max) | -40 - 85 °C |
| Main circuit terminal location | Rear |
| Supplied with protection device | Yes |
| Integrated motor operator | No |
| Frequency range (min-max) | 50-60 Hz |
| Rated voltage range (min-max) | 230-400 V |
| Short-time delay release setting range (min-max) | 1.5 - 10 A |
| Overload release setting range (min-max) | 0.2 - 1 A |
| Operating temperature range (min-max) | -5 - 70 °C |
| Contains battery and/or accumulator | No |
| With trip indicator | No |
| With integrated undervoltage release | No |
| Integrated earth fault protection | No |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz | 70 kA |
| Rated uninterrupted current Iu | 320 A |