Legrand DPX3 moulded case circuit breaker 4P 250 A 36 kA with measurement electronic trip unit IP30 S10 RCD 423478
- BrandLegrand
- SeriesDPX3 250A
- Ultimate breaking capacity Icu36 kA
- Depth112 mm
- Rated current In250 A
- Width140 mm
- Height165 mm
Legrand DPX3 moulded case circuit breaker 4P, 250 A, 36 kA, with measurement, electronic trip unit, reference 423478, RCD, rated current In 250 A, overload release setting range 100…250 A. A moulded case circuit breaker is used to switch distribution circuits and protect them against overloads and short circuits. Main parameters: rated current In 250 A; number of poles 4; breaking capacity Icu 36 kA; overload release setting range 100…250 A; short-circuit release setting range 375…2500 A; number of auxiliary changeover contacts 2; voltage type AC; width 140 mm, height 165 mm, depth 112 mm. Features: integrated earth-fault protection, with trip indicator, supplied with protection device.
| Series | DPX3 250A |
|---|---|
| Ultimate breaking capacity Icu | 36 kA |
| Depth | 112 mm |
| Rated current In | 250 A |
| Width | 140 mm |
| Height | 165 mm |
| Device design | Permanently installed device |
| For TH rail mounting | No |
| Supply direction | Not applicable |
| Colour | Grey |
| Number of poles | 4 |
| Number of auxiliary changeover contacts | 2 |
| Labelling area | No |
| RAL number | 7035 |
| Impact resistance | Not applicable |
| Optional DIN (TH) rail mounting | No |
| Optional motor operator | Yes |
| Terminal marking | No |
| Terminal cross-section (min-max) | 2.5-120 mm² |
| Actuator type | Switch |
| Connection cable type | Flexible or rigid |
| Voltage type | AC |
| Main contact connection type | Pin connection |
| Degree of protection (IP) | IP30 |
| Storage temperature (min-max) | -25-85 °C |
| Main circuit terminal location | Front |
| Supplied with protection device | Yes |
| Integrated motor operator | No |
| Frequency range (min-max) | 50-60 Hz |
| Rated voltage range (min-max) | 230-690 V |
| Overload release setting range (min-max) | 100-250 A |
| Short-circuit release setting range (min-max) | 375-2500 A |
| Operating temperature range (min-max) | -5-70 °C |
| With trip indicator | Yes |
| With integrated undervoltage release | No |
| Integrated earth fault protection | Yes |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz | 36 kA |
| Rated uninterrupted current Iu | 250 A |
Technical data according to the manufacturer's documentation.